Komatsu — HYDRAULIC PUMP

STRUCTURE AND FUNCTION HYDRAULIC PUMP 2. Control of discharge amount If swash plate angle becomes larger, the difference between volumes E and F becomes larger and discharge amount Q increases. Swash plate angle is changed by control piston (5). crease. This screw should be adjusted when the machine doesn’t travel straight or machine maximum speed is little bit wrong. Screw B is the fine adjuster of neutral position of control piston (5). That adjust prevent machine from creep. B SK714-5 SK815-5 B A A 5 5 A 6 6 4 4 RKS00260 10-23 SK714-5 SK815-5 • Control piston (5) move AS valves).

This straigh cylindrical surface to cr • On this pump, maximu 5 6 4 3 RKS00280 • Screw A restricts to the maximum stroke of control p iston (i.e. maximum displacement of each pump). When screw