Komatsu — AIR CONDITIONER CONTROLS

. OPERATION DETAILED CONTROLS AND GAUGES When more than one failure is detected, press the " " or " " portion of temperature setting switch (3) to display the failures in turn. After completing the troubleshooting, press OFF switch (1) again to return to the normal display. If any problem is detected by the self-diagnostic function, contact your Komatsu distributor perform inspection and repair. Function to Switch Set Temperature Display Between Fahrenheit and Celsius It is possible to switch the set temperature display between ° F and ° C.

If the " " and " " portions of temperature setting switch (3) are pressed at the same time for more than 5 seconds while the fan is running, the temperature display will switch between ° F and ° C.

(Note that the unit is not displayed.) 3 - 60 display and failure mode> Display Failure mode E-- No failure E11 Disconnection in recirculated air sensor E12 Short circuit in recirculated air sensor E13 Disconnection in fresh air sensor E14 Short circuit in fresh air sensor E15 Disconnection in coolant temperature sensor E16 Short circuit in coolant temperature sensor E18 Short circuit in sunlight sensor E21 Disconnection in vent sensor E22 Short circuit in vent sensor E43 Problem in vent damper E44 Problem in air mix damper E45 Problem in RECIRC/FRESH air damper E51 Problem in refrigerant pressure Liquid crystal display range °C 18.0 to 32.0 °F 63 to 91