Komatsu — CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT

. MAINTENANCE MAINTENANCE PROCEDURE MAINTENANCE MAINTENANCE PROCEDURE 5. Direct dry compressed air (less than 0.69 MPa (7 kg/cm 2 , 99.4 PSI)) to the outer element from inside along its folds, then direct it from outside along its folds and again from inside. 1) Replace the outer element once a year or when monitor (1) flashes. Replace the inner element at the same time. 2) Check that there is no play in the inner element. If any play is found, push it in properly. 3) Replace both inner and outer elements when the air cleaner clogging monitor (1) lights up soon after installing the cleaned outer element even though it has not been cleaned 6 times. the element.

Do not clean and reinstall an inner element. 5. Install the outer element and the cover. 6. After replacing the element, push the dust indicator button to reset it. The yellow piston will return to its original position. 4 - 19 6. Remove the cloth or tape c 7. If small holes or thinner pa rts are found on the element when ht through it after cleaning, replace NOTICE When cleaning the element, do Do not use an element whose fo Replacing Inner Element 1. First remove the outer elem ent, and then remove the inner element 2. Cover the air connector sid e (outlet side) with a clean cloth or tape. 3. Clean the air cleaner body interior, then remove the cover installed in Step 2 4.

Fit a new inner element to t