EXPLANATION OF COMPONENTS OPERATION PUMP ROOM DOOR, BATTERY ROOM DOOR CAUTION When carrying out inspection and maintenance inside the door, always use the stopper to hold the door open. NOTICE Always keep the door locked except when opening it. 1. Release lock (1) of the door. For details, see "CAP, COVER WITH LOCK (PAGE 3- 25)". 2. Hook your finger in catch (2) and open door (3). 3. Remove stopper (4) from spring catch (5). 4. Set so that the cushion of stopper (4) contacts the out- side circumference of the machine, then lower stopper (4). 5. When closing door (3), secure stopper (4) to spring catch (5), then close the door. 6. Lock the door.
REMARK The pump room door is on the right side of the machine; the battery room door is on the left side of the machine. 3-28