Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Sensing system Differential pressure switch - Short circuit to B+ (A.10.A.95.81 - G.30.B.54) AFX8010 E0006-03 - Reservoir Oil Filter Restriction Switch Cause: The return filter bypass pressure switch (S32) circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HYDRAULIC" sort menu, and select "RES FILTER SW" to check the voltage range. The normal operating range for the return filter bypass circuit is 1.8 - 10.0 volts A.

If the voltage reading is 10.0 volts or greater, continue with Step 2 . B. If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 4 . 2. Disconnect the return filter bypass pressure switch connector X239 . A. If the voltage drops below 10 volts , the short is in the sensor, or sensor wiring. Replace the sensor. B. If the voltage is above 10.0 volts , continue with Step 3 . 3. Disconnect the straw hood front (SW) harness from the main frame (MF) harness at connector X024 . A.

If the voltage drops back within range, the short is in the straw hood front (SW) harness between connector X024 and connector X239 wire 447 yellow. Locate the short and repair. B. If the voltage remains above 10.0 volts , the short is in the main frame (MF) harness between connector X024 and connector X019 pin J2-34 wire 447 yellow. Locate the short and repair. 4. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9665 1 27/05/2004 A.10.A / 8 7