Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Sensing system Temperature sensor - Short circuit to B+ (A.10.A.95.90 - G.30.B.54) AFX8010 E0024-03 - Hydraulic Reservoir Temperature Sensor Cause: The hydraulic reservoir temperature (B-18) is shorted to high source. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HYDRAULIC" sort menu, and select "RES TEMP SEN" to check the voltage range. The proper voltage range is - 0.5 - 4.9 volts A. If the voltage reading is above 5.2 volts , continue with Step 2 . B.

If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 4 . 2. Disconnect the hydraulic reservoir temperature sensor connector X103 . A. If the voltage drops to 4.9 - 5.2 volts , the short is in the sensor, or sensor wiring. Replace the sensor. B. If the voltage remains high, continue with Step 3 . 3. Disconnect the gearbox (GB) harness from the main frame (MF) harness at connector X011 . A. If the voltage drops to 4.9 - 5.2 volts , the short is in the gearbox (GB) harness between connector X011 and connector X103 wire 446 yellow. Locate the short and repair. B.

If the voltage remains high, the short circuit is in the main frame (MF) harness between connector X011 and connector X020 J2-24 wire 446 yellow. Locate the short and repair. 4. Visually inspect harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase fault code and continue operation. 9665 1 27/05/2004 A.10.A / 9 0