Case IH AFX8010 — LUBRICATION SYSTEM

POWER PRODUCTION - LUBRICATION SYSTEM Sensing system Oil temperature - Short circuit to B+ (B.60.A.95.92 - G.30.B.54) AFX8010 E0153-03 - Engine Oil Temperature Sensor Cause: The engine oil temperature sensor (B-03) circuit is shorted to 12 volts. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "ENGINE" sort menu, and select "OIL TEMP SEN" to check the voltage range. The proper voltage range is - 0.5 - 4.9 volts . A. If the voltage reading is high out of range (> 5.2 volts ), continue with Step 2 . B.

If the voltage reading is within the proper limits, continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the engine oil temperature sensor connector X311 . A. If the voltage drops to 4.9 - 5.2 volts , the short is in the sensor or sensor wiring. Replace the sensor. 3. Disconnect the Iveco engine harness from the engine (EN) harness at connector X197 . B.

If the voltage remains high, continue with Step 3 . A. If the voltage drops to 4.9 - 5.2 volts , the short is in the Iveco engine harness between connector X197 pin 9 and connector X311 pin 1 on the blue wire. Locate the short and repair. B. If the voltage remains high, continue with Step 4 . 4. Disconnect the engine (EN) harness from the main frame (MF) harness at connector X010 . A. If the voltage drops to 4.9 - 5.2 volts , the short is in the engine (EN) harness between connector X010 pin 10 and connector X197 pin 9 wire 504 yellow. Locate the short and repair. B.

If the voltage remains high, the short circuit is in the main frame (MF) harness between connector X010 pin 10 and connector X016 pin J2-27 wire 504 yellow. Locate the short and repair. 5. Operate the machine while monitoring Universal Display Plus monitor. A. If no high out of range readings are indicated, erase the fault code and continue operation. 9676 1 27/05/2004 B.60.A / 13