POWER PRODUCTION - STARTING SYSTEM Start control Safety switch - Short circuit to ground (B.80.A.90.81 - G.30.B.53) AFX8010 E0164-04 - Ground Drive Hydro Voltage Supply Cause: Low battery voltage to CCM2 through the Neutral switch S22, or the Ground Drive Hydro Voltage Supply circuit is shorted to a ground. Possible failure modes: 1. Loose or corroded connections, or damaged wires. 2. Batteries are discharged, and/or alternator/regulator failure. 3. Supply wiring shorted to ground. 4. Controller internal failure (internal regulator failure). Solution: 1. Key switch in "Off" position. Check the condition of fuse F42. A. If fuse F42 is okay, continue with Step 3 . B.
If the fuse has failed, go to Step 2 . 2. Replace the failed fuse F42. A. If the fuse is okay, continue with Step 3 . B. If the fuse immediately fails again, a short to ground exists in wire 010 red to Cab Power Relay K-26 pin 3. Locate short and repair. 3. Key switch in "On" position. Check the condition of fuse F48. A. If fuse F48 is okay, continue with Step 5 . 4. Replace the failed fuse F48. B. If the fuse is blown, go to Step 4 . A. If the fuse is okay, continue with Step 5 . B. If the fuse immediately fails again, a short to ground exists in one of the following wires:
- wire 109 orange, fuse F48 to relay K28, terminal 3 - wire 108 orange, fuse F48 through connector X001 pin 3 to RH harness splice - wire 358 orange, RH harness splice to feeder engage switch S-31 connector X056 pin 2 - RH console power wires to propulsion handle S-03, front switch panel A-13, rear switch panel A-18 and RHM connector X026 pins 4 & 5 - wires 300 orange, 110 orange & 1180 orange, RH harness splice across separator switch S-30 to neutral switch S-02 connector X059 pin 3 Locate the short and repair. 5. Move the propulsion handle (MFH) out of neutral, and observe the fuse F48. A. If the fuse is okay, continue with Step 6 . B.
If the fuse immediately fails, a short to ground exists in wire 113 yellow from the neutral switch S22 connector X059 pin 5 through connector X001 pin 17 to CCM2 X015 pin J1-17. Locate short and repair. 6. Key switch in "Off" position. Check the voltage at fuse F42 using a multi-meter. A. If the voltage reading is between 10 and 18 volts , continue with Step 7 . 9677 1 27/05/2004 B.80.A / 25