POWER TRAIN - TRANSMISSION Mechanical Sensing system Shift position sensor - Short circuit to B+ (C.20.B.95.81 - G.30.B.54) AFX8010 E0130-03 - Trans Shift Position 2 Sensor Cause: The transmission shift position sensor B-37 "2" circuit is shorted to 12 volts. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts. 2. Controller internal failure (internal regulator failure) Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "TRANSMISSION" sort menu, and select "POS 2 SEN" to check the voltage range. The proper voltage when in shift position 2 is 5.6 - 7.3 volts . The proper voltage when not in shift position 2 is 0.5 - 5.6 volts . A.
If the voltage reading is high (> 9 volts ) out of range, continue with step 2 . B. If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue troubleshooting at step 4 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector is fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the transmission shift position sensor connector X093 at the transmission. The voltage indicated should be 7.3 - 9 volts . A.
If the voltage drops to 7.3 - 9 volts , there is a short in the sensor or sensor wiring. Replace the sensor. To temporarily bypass the sensor, continue with step 5 . B. If the voltage remains high (> 9 volts ) out of range, continue with step 3 . 3. Disconnect the lower frame (LF) harness from the front frame (FF) harness at connector X023 . A. If the voltage drops to 7.3 - 9 volts , there is a short in the lower frame (LF) harness between connector X023 pin 9 and connector X093 pin 3 wire 406 yellow. Locate the short and repair. B.
If the voltage remains high (> 9 volts ) out of range, there is a short in the front frame (FF) harness between connector X023 pin 9 and connector X017 pin J3-37 wire 406 yellow. Locate the short and repair. 4. Operate the transmission shift gear switch to change the transmission gears, and monitor the "POS 2 SEN" voltage readings on the Universal Display Plus. A. If a high (> 9 volts ) voltage reading is now viewed, note which gear position generated the high voltage. Continue the troubleshooting at step 2 . B. If a high (> 9 volts ) voltage reading cannot be generated, clear the fault code and continue operation. 5.
If one sensor in the transmission shift position sensor has failed, it is possible to temporarily bypass that circuit to restore partial operation until the sensor can be replaced. A. Use a jumper wire to create a short circuit between connector X093 pin 3 ("POS 2 SEN") and pin 6 (common circuit ground). The fault code E0130-04 - Trans Shift Position 2 Sensor should now be displayed, and the operator can continue operation without this gear. 9680 1 27/05/2004 C.20.B / 116