Case IH AFX8010 — PROCESS DRIVE Primary process drive

POWER TRAIN - PROCESS DRIVE Primary process drive Clutch - Unidentified failure (C.50.B.46 - G.30.B.46) AFX8010 E0180-11 - Beater / Chopper Valve Cause: The Beater / Chopper Valve (L-22) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad solenoid. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" or "GRAIN HANDLING" sort menu, and select "BEAT/CHOP VLV" to monitor the current flow. Use the "COMMAND" and "ENGAGE" functions to power the circuit at 100% output. The proper current is approximately 1.0 - 1.5 amps . A.

If the current reading goes to maximum, and then back to zero, the circuit is shorted to ground and the software has shut off the output to protect the module and wiring. Continue with Step 2 . B. If the reading is 0 amps , the circuit is open. Continue with Step 5 . 2. Disconnect connector X450 . Use a multimeter to check between connector X450 pin A (valve side) and chassis ground. C. If the reading is within the proper range, the circuit is working properly. Continue with Step 11 . A. If there is continuity, the thresher clutch solenoid is shorted to ground. Replace the solenoid. B. If there is no continuity, continue with Step 3 . 3.

Use a multimeter to check for continuity between connector X450 pin A (harness side) and chassis ground. Flex the gearbox (GB) harness between the clutch valve and connector X011 while making this check. A. If there is continuity to ground, continue with Step 4 . B. If there is no continuity to ground, erase the fault code and continue operation. 4. Disconnect connector X011 . Use a multimeter to check for continuity between connector X011 pin 14 and chassis ground. Flex the main frame (MF) harness between the connector X011 and connector X016 while making this check. A.

If there is no continuity to ground, the short to ground is in the gearbox (GB) harness between connector X011 and connector X450 wire 878 white. Locate the short and repair. B. If there is continuity to ground, the short to ground is in the main frame (MF) harness between connector X011 and connector X016 J2-30 wire 878 white. Locate the short and repair. 5. Disconnect connector X450 . Use a multimeter to check the resistance of the thresher clutch valve coil between connector X450 pins A & B. The proper resistance range is 7.2 - 11.2 ohms . A. If there is no continuity, replace solenoid. 6.

Use a multimeter to check for continuity between connector X450 pin B (harness side) and chassis ground. Flex the gearbox (GB) harness between the clutch valve and connector X011 while making this check. B. If the coil is within specification, continue with Step 6 . A. If there is no continuity to ground, continue with Step 7 . 9683 1 27/05/2004 C.50.B / 24