TRAVELLING - REAR AXLE Hydrostatic motor - Disassemble (D.12.A.28 - F.10.A.25) AFX8010 IMPORTANT: Cleanliness is most important when servicing cam lobe motors. Always use clean tools and work in a clean environment. Wash all internal parts in clean solvent and dry thoroughly with compressed air. DO NOT use rags or paper towels. Wrap parts in clean paper and keep them in a clean area prior to assembly. If more than one motor is being serviced, work on each one separately. DO NOT mix parts. 1. Place motor on a work bench resting on the C-frame. Be sure all hydraulic oil is drained from the motor. Loosen but do not yet remove the sixteen M16 socket head cap screws (1) .
Remove C-frame on steerable motor Hydrostatic motor - Remove (D.12.A.28 - F.10.A.10) . 20042859 1 2. Remove the sixteen M16 x 100mm socket head cap screws (4) from the motor. Remove the M8 cap screw and washer (1) and install the valve retainer tool (2) . ATTENTION: Before separating the motor components mark the outside of the components with an alignment mark (3) for re-assembly. 20042860 2 9687 1 27/05/2004 D.12.A / 25