Case IH AFX8010 — PARKING BRAKE Hydraulic

TRAVELLING - PARKING BRAKE Hydraulic Limit valve - Unidentified failure (D.32.C.15 - G.30.B.46) AFX8010 E0191-11 - Brake Limiting Valve Cause: The brake limiting valve (L-32) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad solenoid. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "BRAKES" sort menu, and select "LIMIT VLV". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A.

If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 9 . 2. Disconnect connector X329 . Use a multimeter to check the resistance of the brake limiting valve coil (L32). The proper resistance range is 3 - 5 ohms . A. If there is zero resistance, the brake limiting solenoid is shorted internally. Replace the solenoid. B. If there is infinite resistance, the brake limiting solenoid is open. Replace the solenoid. C. If the resistance is correct, continue with Step 3 . 3.

Use a multimeter to check for continuity between connector X329 pin A (harness side) and chassis ground. Flex the main frame (MF) harness while making this check. A. If there is continuity to ground, the short to ground is in the main frame (MF) harness between connector X329 and connector X019 pin J2-7 wire 1504 white. Locate the short and repair. B. If there is no continuity to ground, continue with Step 5 . 4. Use a multimeter to check for continuity between connector X329 pin B (harness side) and chassis ground. Flex the main frame (MF) harness while making this check. A.

If there is no continuity to ground, there is an open circuit in the main frame (MF) harness between connector X329 pin B and the front frame ground #2 wire 1505 black. Locate the open and repair. B. If there is continuity to ground, continue with Step 7 . 5. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the brake limiting valve. Use a multimeter to check for 12 volts between connector X329 pin A and chassis ground. A. If 12 volts is not present there is an open circuit in the main frame (MF) harness between connector X329 pin A and connector X019 pin J2-7 wire 567 white. Locate the open and repair. B.

If 12 volts is found, continue with Step 9 . 6. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9691 1 27/05/2004 D.32.C / 25