Case IH AFX8010 — USER PLATFORM

BODY AND STRUCTURE - USER PLATFORM NOTE: The batteries must be fully charged and all connections clean and tight. Use a multimeter (DVOM) for these tests. For battery testing and service, see the battery section in the service manual. CAUTION DO NOT use a self-powered test light for any of these tests. Use of a self-powered test light can cause damage to components in this system. WARNING Before performing any of the electrical tests, be sure all operating controls are in neutral or park lock position. This will eliminate accidental movement of the machine or start-up of power driven equipment.

A - WIPER RELAY TEST E.34 / 11 Test Point Good Reading Possible Cause of Bad Reading 1 Key Switch S-02 “ON”. Check for 12 volts at Wiper Relay K-06 (pin 1). 12 volts Go to next test point. Open circuit 123 (OR) between Key Switch S-02 connector X068 (pin 4) and Wiper Relay K-06 (pin 1). 2 Check for 12 volts at Wiper Relay K-06 (pin 3). 12 volts Go to next test point. Open circuit 70 (RD) between Fuse F04 and Wiper Relay K-06 (pin 3). Blown Fuse F04. 3 Key Switch S-02 “OFF” Check for continuity to Ground at Wiper Relay K-06 (pin 2). Less than 1 ohm. Go to next test point. Open circuit 242 (BK) between Wiper Relay K-06 (pin 2) and Ground. 4 Check for 12 volts at Wiper Relay K-06 (pin 5).

12 volts Go to next test point. Wiper Relay K-06. Go to next test point. Short circuit 272 (OR) between Wiper Relay K-06 (pin 5) and Wiper Switch S-20 connector X135 (pin 2). A short will cause Fuse F04 to blow. 5 Check for 12 volts at Wiper Switch S-20 connector X135 (pin 2). 12 volts If good reading, power feed to Wiper Switch S-20 is operating properly. Open or short circuit 272 (OR) between Wiper Relay K-06 (pin 5) and Wiper Switch S-20 connector X135 (pin 2). Check in-line connector X002 (pin 14) for connection.