BODY AND STRUCTURE - USER PLATFORM E.34 / 28 Test Point Good Reading Possible Cause of Bad Reading 6 Hold Mirror Adjust Switch S-27 in DOWN position. Check the resistance between German Mirror M-30 (pin 2) and ground. Less than 1 ohm If good reading, go to next test point. Open in circuit 966 (GY) between Mirror Select Switch S-57 connector X178 (pin 1) and German Mirror M-30 (pin 2). Check the X036 (pin 19) and X287 (pin 2) in-line connectors for connection. Mirror Adjust Switch S-27. Perform A - Mirror Adjust Switch Test, steps 3 and 14. 7 Hold Mirror Adjust Switch S-27 in DOWN position. Check the voltage at German Mirror M-30 (pin 2). 12 volts If good reading, go to next test point.
Short to ground which affects circuit 966 (GY) or open in circuit 966 (GY) between Mirror Select Switch S-57 connector X178 (pin 1) and German Mirror M-30 (pin 2). A short to ground will blow Fuse F09. Check the X036 (pin 19) and X287 (pin 2) in-line connectors for connection. Mirror Select Switch S-57. Perform B - Mirror Select Switch Test. 8 Hold Mirror Adjust Switch S-27 in UP position. Check the resistance between German Mirror M-30 (pin 4) and ground. Less than 1 ohm If good reading, and German mirror does not operate properly, replace German mirror assembly. Open in circuits 963 (GY) or 957 (WH) between Mirror Adjust Switch S-27 connector X126 (pin E) and German Mirror M-30 (pin 4).
Check the X036 (pin 21) and X287 (pin 4) in-line connectors for connection. Mirror Adjust Switch S-27. Perform A - Mirror Adjust Switch Test, steps 3 and 19.