BODY AND STRUCTURE - ENVIRONMENT CONTROL Heating, ventilation and air-conditioning Receiver/drier - Static description (E.40.D.36 - C.30.A.20) AFX8010 The receiver/dryer located on the right side of the frame, is a storage tank that receives the high pressure liquid refrigerant from the condenser through an inlet line. The dryer section contains a desiccant to absorb moisture but can only absorb a limited amount of moisture before reaching a saturation point. The ability to retain moisture absorbed is dependent upon temperature. As the outside temperature increases, the ability to retain absorbed moisture decreases.
This is why an air conditioning system with a saturated dryer may operate satisfactorily when outside temperatures are low, but stop cooling when the temperature increases. The refrigerant exits the receiver/dryer through an outlet connection and flows to the thermostatic expansion valve. 10036358 1 NOTE: Any moisture in the air conditioning system is extremely harmful. Moisture not absorbed by the dryer will circulate with the refrigerant. Droplets may collect and freeze in the thermostatic expansion valve restricting refrigerant flow. The moisture circulating in the system may also react with the refrigerant to form hydrochloric acid. NOTE:
In general, the receiver/dryer should be replaced any time the system is opened for service. 9702 1 27/05/2004 E.40.D / 10