Case IH AFX8010 — ENVIRONMENT CONTROL Heating, ventilation and air-conditioning

BODY AND STRUCTURE - ENVIRONMENT CONTROL Heating, ventilation and air-conditioning 8. Locate the separator/air filter housing inside the cavity next to the left cab door. 10036362 7 9. Release the housing end cap lock by pulling it away from the filter. Rotate the housing end cap counterclockwise until it can be removed. 10036363 8 10. Pull the filter element out of the filter housing. 9702 1 27/05/2004 E.40.D / 16