Case IH AFX8010 — ENVIRONMENT CONTROL Heating, ventilation and air-conditioning

BODY AND STRUCTURE - ENVIRONMENT CONTROL Heating, ventilation and air-conditioning Condenser - Remove (E.40.D.32 - F.10.A.10) AFX8010 1. Recover refrigerant in accordance with local regulations. 2. Open the rotary screen door to gain access to the air conditioning condenser. 3. Disconnect and cap the refrigerant lines from the condenser (1) . The fittings are different sizes, labeling should not be required. NOTE: Use the proper tools to remove the lines correctly and prevent the condenser lines twisting. 40034893A5 1 4. Remove the condenser (2) by removing the two pins (1) from the hinges. 40034893B5 2 9702 1 27/05/2004 E.40.D / 27