BODY AND STRUCTURE - ENVIRONMENT CONTROL Heating, ventilation and air-conditioning Expansion valve - Install (E.40.D.34 - F.10.A.15) AFX8010 1. Set the thermal expansion valve into position and secure it with two cap screws. Apply refrigerant oil to the o-rings and connect the four refrigerant lines, temperature sensor (1) , ball and spring (2) , on to evaporator (3) , from evaporator (4) , on to compressor (5) , from condenser (6) . 20036386A5 1 2. Wrap the valve and the attached lines with insulation. 10036360 2 3. Recharge the refrigerant system in accordance with the Recharge/Refilling procedure in this section. 4.
Set the ventilation system shield into place and secure using five cap screws (1) . 10036357A5 3 9702 1 27/05/2004 E.40.D / 36