BODY AND STRUCTURE - SAFETY SECURITY ACCESSORIES Safety Sensing system Rear ladder sensor - Short circuit to ground (E.50.B.95.80 - G.30.B.53) AFX8010 E0026-04 - Rear Ladder Sensor Cause: The rear ladder sensor (B-22) circuit is shorted to ground. Possible failure modes: 1. Sensor supply wiring shorted to ground. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "GRAIN HANDLING" or "THRESHING" sort menu, and select "REAR LADDER SEN" to check the voltage range.
The proper voltage for sensor when rear ladder is up is 0.5 - 3.9 volts The proper voltage for sensor when rear ladder is down is 3.9 - 4.9 volts The proper voltage with sensor disconnected is 4.9 - 5.2 volts . A. If the voltage reading is low ( 0 - 0.5 volts ), continue with Step 2 . B. If the voltage reading is within the proper limits,. continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. 2. Disconnect the rear ladder sensor connector X251 . A.
If the voltage increases to 4.9 - 5.2 volts , the short to ground is in the sensor or sensor wiring. Replace the sensor. B. If the voltage remains low, continue with Step 3 . 3. Disconnect the straw hood rear (SH) harness from the straw hood front (SW) harness at connector X071 . A. If the voltage increases to 4.9 - 5.2 volts , the short to ground is in the straw hood rear (SH) harness between connector X071 pin 11 and connector X251 pin 2 wire 570 yellow. Locate the short and repair. B. If the voltage remains low, continue with Step 4 . 4. Disconnect the straw hood front (SW) harness from the main frame (MF) harness at connector X024 . A.
If the voltage increases to 4.9 - 5.2 volts , the short is in the straw hood front (SW) harness between connector X024 pin 16 and connector X071 pin 11 wire 570 yellow. Locate the short and repair. B. If the voltage remains low, the short to ground is in the main frame (MF) harness between connector X024 pin 16 and connector X019 pin J2-17 wire 570 yellow. Locate the short and repair. 5. Visually inspect harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase fault code and continue operation. 9703 1 27/05/2004 E.50.B / 10