Case IH AFX8010 — LIFTING

TOOL POSITIONING - LIFTING 6. Key off. Use a multimeter to test for continuity between connector X020 pin J3-18 on CCM1 and chassis ground. There should be low resistance ( 1 ohms ) to ground. A. If no continuity is found, or there is high resistance (> 1 ohms ) to ground, the CCM1 module is not supplying a ground path for the sensor due to an internal failure. Replace the CCM1 module. B. If continuity is found, the ground path for the sensor tests okay. Reconnect all connectors and retest for continuity to ground at Step 2 . 7. Disconnect connector X306, and use a multimeter to test for voltage on connector X306 pin 2. There should not be any voltage present. A.

If no voltage is found, continue with Step 8 . B. If high (> 4.7 volts ) voltage is found, continue with Step 7 . 8. Disconnect connector X032 , and use a multimeter to test for voltage on the feeder (FE) harness end of connector X032 pin 2. There should not be any voltage present. A. If no voltage is found, there is a short to voltage in the header (HH) harness between connector X306 and connector X032 wire 739 yellow. Locate the short and repair. B. If high (> 4.7 volts ) voltage is found, continue with Step 7 . 9. Disconnect connector X007 , and use a multimeter to test for voltage on the front frame (FF) harness end of connector X007 pin 16. There should not be any voltage present. A.

If high (> 4.7 volts ) voltage is found, there is a short to high voltage in the front frame (FF) harness between connector X007 pin 16 and connector X020 pin J3-22 wire 739 yellow. Locate the short and repair. B. If no voltage is found, there is a short to high voltage in the feeder (FE) harness between connector X032 pin 2 and connector X007 pin 16 wire 739 yellow. Locate the short and repair. 10. Disconnect connector X306, and use a multimeter to test for voltage on connector X306 pin 3. There should be 5 volts present. A. If 5 volts is found, continue with Step 11 . B. If high (> 5 volts ) voltage is found, continue with Step 11 . NOTE:

This supply circuit is also used to supply power to the lateral tilt potentiometer R-02 and the shoe leveling sensor in the shoe leveling actuator M03, so a short to 12 volts anywhere on the supply circuit will activate this error code. 11. Disconnect connector X032 , and use a multimeter to test for voltage on the feeder (FE) harness end of connector X032 pin 5. There should be 5 volts present. A. If 5 volts is found, there is a short to high voltage in the header (HH) harness between connector X306 and connector X032 wire 848 pink. Locate the short and repair. B. If high (> 5 volts ) voltage is found, continue with Step 9 . 12.

Disconnect connector X007 , and use a multimeter to test for voltage on connector X007 pin 22. There should be 5 volts present. A. If 5 volts is found, there is a short to high voltage in the feeder (FE) harness between connector X032 pin 5 and connector X007 pin 22 wire 848 pink or 757 pink. Locate the short and repair. B. If high (> 5 volts ) voltage is found, continue with Step 10 . 13. Disconnect connector X023 , and use a multimeter to test for voltage on the front frame (FF) harness end of connector X023 pin 17. A.

If 5 volts is found, there is a short to high voltage in the lower frame (LF) harness between connector X088 pin A on the shoe leveling actuator M03 and connector X023 pin 17 wire 727 pink. Locate the short and repair. 9706 1 27/05/2004 G.10.A / 22