Case IH AFX8010 — LIFTING

TOOL POSITIONING - LIFTING Sensing system Right tool position sensor - Short circuit to ground (G.10.A.95.84 - G.30.B.53) AFX8010 E0019-04 - Right Header Height / Tilt Sensor Cause: The right height/tilt sensor (R-13) circuit is shorted to ground. Possible failure modes: 1. Sensor signal wiring is shorted to ground. 2. Module internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HDR HEIGHT/TILT" sort menu, and select "RIGHT SEN" to check the voltage range.

Manually raise and lower the header against the ground several times while monitoring the voltage; the voltage should stay within range, and should change smoothly with header sense plate movement. The voltage range for a properly adjusted sensor is 0.2 - 4.7 volts . A. If the voltage reading is low ( 0.2 volts ) out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the circuit may not be shorted at this time. Continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed.

Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect connector X306, and use a multimeter to test for continuity between connector X306 pin 2 and chassis ground. There should not be continuity to ground. A. If there is no continuity to ground, continue with Step 5 . B. If there is continuity to ground, continue with Step 3 . 3. Disconnect connector X032 , and use a multimeter to test for continuity between the feeder (FE) harness end of connector X032 pin 2 and chassis ground. There should not be continuity to ground. A.

If there is no continuity to ground, there is a short to ground in the header (HH) harness between connector X306 and connector X032 wire 739 yellow. Locate the short and repair. B. If there is continuity to ground, continue with Step 4 . 4. Disconnect connector X007 , and use a multimeter to test for continuity between the front frame (FF) harness end of connector X007 pin 16 and chassis ground. There should not be continuity to ground. A. If there is continuity to ground, there is a short to ground in the front frame (FF) harness between connector X007 pin 16 and connector X020 pin J3-22 wire 739 yellow. Locate the short and repair. B.

If there is no continuity to ground, there is a short to ground in the feeder (FE) harness between connector X032 pin 2 and connector X007 pin 16 wire 739 yellow. Locate the short and repair. 5. Operate the machine while monitoring the Universal Display Plus "DIAG" screen. A. If no low out of range readings are indicated, erase the fault code and continue operation. 9706 1 27/05/2004 G.10.A / 27