Case IH AFX8010 — LIFTING

TOOL POSITIONING - LIFTING Sensing system Right tool position sensor - Out of range (G.10.A.95.84 - G.30.C.24) AFX8010 E0019-07 - Right Header Height / Tilt Sensor Cause: The right height/tilt sensor (R-13) circuit is not moving when the feeder is moving. Possible failure modes: 1. The right height/tilt sensor is mechanically bound up. Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HDR HEIGHT/TILT" sort menu, and select "RIGHT SEN" to check the voltage range. Manually raise and lower the header against the ground several times while monitoring the voltage; the voltage should stay within range, and should change smoothly with header sense plate movement.

The voltage range for a properly adjusted sensor is 0.2 - 4.7 volts . A. If the voltage reading does not change, the header protection plates are locked up, the sensor mechanical linkage is unhooked, or the sensor is mechanically bound up. Inspect the header plates and sensor linkage, and free up as necessary. B. If the voltage reading changes with feeder and header movement, erase the fault code and continue operation. 9706 1 27/05/2004 G.10.A / 35