TOOL POSITIONING - LIFTING Sensing system Centre tool position sensor - Out of range (G.10.A.95.83 - G.30.C.24) AFX8010 E0027-07 - Left Center Header Height Sensor Cause: The center height/tilt sensor (R-19) circuit is not moving when the feeder is moving. Possible failure modes: 1. The center height/tilt sensor is mechanically bound up. Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HDR HEIGHT/TILT" sort menu, and select "LFT CENTER SEN" to check the voltage range. Manually raise and lower the header against the ground several times while monitoring the voltage; the voltage should stay within range, and should change smoothly with header sense plate movement.
The voltage range for a properly adjusted sensor is 0.2 - 4.7 volts . A. If the voltage reading does not change, the header protection plates are locked up, the sensor mechanical linkage is unhooked, or the sensor is mechanically bound up. Inspect the header plates and sensor linkage, and free up as necessary. B. If the voltage reading changes with feeder and header movement, erase the fault code and continue operation. 9706 1 27/05/2004 G.10.A / 65