Case IH AFX8010 — LEVELLING

TOOL POSITIONING - LEVELLING Sensing system Position sensor - Short circuit to B+ (G.30.A.95.81 - G.30.B.54) AFX8010 E0029-03 - Header Tilt Angle Sensor Cause: The lateral float sensor (R-02) circuit is shorted to high voltage, or the sensor ground is open. Possible failure modes: 1. Sensor supply or signal wiring is shorted to high voltage (12V). 2. Sensor ground wiring is open. 3. Module internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HDR HEIGHT/TILT" sort menu, and select "TILT ANGLE SEN" to check the voltage range.

Tilt the feeder cradle side to side several times while monitoring the voltage; the voltage should stay within range, and should change smoothly with feeder cradle movement. The proper voltage range for a properly adjusted sensor is 0.2 - 4.7 volts . A. If the voltage reading is high (> 4.7 volts ) out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the circuit may not be shorted at this time. Continue the troubleshooting at Step 11 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.

Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Key off. Disconnect connector X081 , and use a multimeter to test for continuity to ground on connector X081 pin 3. There should be low resistance ( 1 ohms ) to ground. A. If continuity is found ( 1 ohms ), continue with Step 6 . B. If no continuity is found, or there is high resistance (> 1 ohms ) to ground, continue with Step 3 . 3. Key off. Disconnect connector X007 . Use a multimeter to test for continuity between connector X007 pin 12 and chassis ground. There should be low resistance ( 1 ohms ) to ground. A.

If no continuity is found, or there is high resistance (> 1 ohms ) to ground, continue with Step 4 . B. If continuity is found, there is an open circuit in feeder (FE) harness between connector X081 pin 3 and connector X007 pin 12 wire 745 blue or 749 blue. Locate the open and repair. 4. Key off. Carefully remove connector X020 from the bottom of CCM1. Use a multimeter to test for continuity between connector X007 pin 12 and connector X020 pin J3-18. A. If continuity is found, continue with Step 5 . B. If no continuity is found, there is an open circuit in front frame (FF) harness between connector X007 pin 12 and connector X020 pin J3-18 wire 749 blue or 501 blue.

Locate the open and repair. 5. Key off. Use a multimeter to test for continuity between connector X020 pin J3-18 on CCM1 and chassis ground. There should be low resistance ( 1 ohms ) to ground. A. If no continuity is found, or there is high resistance (> 1 ohms ) to ground, the CCM1 module is not supplying a ground path for the sensor due to an internal failure. Replace the CCM1 module. B. If continuity is found, the ground path for the sensor tests okay. Reconnect all connectors and retest for continuity to ground at Step 2 . 9708 1 27/05/2004 G.30.A / 6