Case IH AFX8010 — FEEDING Header feeding

CROP PROCESSING - FEEDING Header feeding A. If there is no power, there is an open circuit on wire 028 red, from the fuse panel through connector X031 pin 4 to connector X017 pin J3-7 on CCM2 module. Locate the open and repair. After repair, go to Step 20 . 20. Test for continuity to ground at connector X017 pin J3-16 on the CCM2 module under the cab. B. If there is power, go to Step 20 . A. If there is no continuity to ground, there is an open circuit in the front frame (FF) harness between connector X017 pin J3-16 and the front frame ground #2 wire 515 black or 538 black. Locate the open and repair. After repair, go to Step 21 . 21.

Once it has been verified that power is being supplied to the module, recheck the circuit operation as described in Step 1. B. If there is continuity to ground, go to Step 21 . A. If the fuse fails during the testing, a short to ground on the circuit is causing the fuse to fail. Start the troubleshooting at Step 3 to locate the short to ground. 9711 1 27/05/2004 K.25.D / 6