Case IH AFX8010 — ELECTRICAL POWER SYSTEM

DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM DE_HDP24-24-31P 23 DE_HDP26-24-31S 24 9667 1 27/05/2004 A.30.A / 24 Cavity Circuit ID Description 1 759 (WH) CCM1 J3-4 to header height accumulator L-06 2 1119 (BL) CCM2 J3-12 to signal valve L-43 3 722 (YE) CCM1 J3-25 to header lift pressure B-29 4 open 5 1503 (YE) CCM1 J2-26 to brake wear switches S-55, S-56 and brake fluid level switch S-49 6 415 (YE) Spreader position B-11 to CCM1 J3-37 7 1197 (YE) Park brake pressure B-53 to CCM2 J3-34 8 485 (YE) Unload cradle B-38 to CCM1 J3-36 9 1053 (WH) CCM1 J3-15 to Feeder Ring to Frame clutch L-50 10 1051 (WH) CCM1 J3-21 to feeder pump swash minus L-48 11 879 (GY) CCM2 J3-21 to ground speed hydrostat L-23 12 880 (WH) CCM2 J3-31 to ground speed hydrostat L-23 13 555 (BL) CCM1 J2-10 to lateral tilt solenoids L-18, L-19 14 open 15 613 (PU) Flasher module A-05 to LH header flashing lamp E-01 (NA only) 16 618 (PU) Flasher module A-05 to RH header flashing lamp E-02 (NA only) 17 open 18 1205 (OR) Fuse F-45 to Feeder RPM B-14 and Cleaning Fan RPM B-16 19 open 20 open 21 open 22 881 (BL) CCM2 J3-35 to ground speed hydrostat L-23 23 1050 (WH) CCM1 J3-31 to feeder pump swash plus L-49 24 1201 (BK/WH) Feeder RPM B-14 to battery clean ground