Case IH AFX8010 — FEEDING Header feeding

CROP PROCESSING - FEEDING Header feeding 3. Fault codes indicate circuit fault due to short to ground. Disconnect the draper header solenoid connector X440. Use a multimeter to check for continuity between terminals 1 or 2 on the solenoid connector and a known good ground. There should be no continuity to ground. A. There is continuity to ground, indicating a short to ground in the solenoid. Replace the solenoid. 4. Disconnect the batteries by removing the negative battery cables. Use a multimeter to check for continuity between connector X440 pin 2 and chassis ground. B. If there is no continuity to ground, continue with Step 4 . A. If continuity is found, continue with Step 5 . B.

If no continuity is found, continue with Step 7 . NOTE: The CCM module connects both sides of the circuit to ground when in neutral to "lock" the circuit in position. Power must be removed from the module prior to testing for short to ground condition on the circuit to remove this ground path. 5. Disconnect connector X032 . Use a multimeter to check for continuity between connector X032 pin 26 and chassis ground. A. If no continuity is found, the short to ground is in the header (HH) harness between connector X032 pin 26 and connector X440 pin 2. Locate the short and repair. B. If continuity is found, continue with Step 6 . 6. Disconnect connector X007 .

Use a multimeter to check for continuity between connector X007 pin 19 and chassis ground. A. If no continuity is found, the short to ground is in the feeder (FE) harness between connector X032 pin 26 and connector X007 pin 19 wire 711 gray. Locate the short and repair. B. If continuity is found, the short to ground is in the front frame (FF) harness between connector X007 pin 19 and connector X017 pin J3-6 wire 711 gray. Locate the short and repair. 7. Use a multimeter to check for continuity between connector X440 pin 1 and chassis ground. A. If continuity is found, continue with Step 8 . B. If no continuity is found, recheck the circuit for continuity to ground at Step 3 . 8.

Disconnect connector X032 . Use a multimeter to check for continuity between connector X032 pin 20 and chassis ground. A. If no continuity is found, the short to ground is in the header (HH) harness between connector X440 pin 1 and X032 pin 20. Locate the short and repair. B. If continuity is found, continue with Step 9 . 9. Disconnect connector X007 . Use a multimeter to check for continuity between connector X007 pin 3 and chassis ground. A. If no continuity is found, the short to ground is in the front frame (FF) harness between connector X007 pin 3 and connector X017 pin J3-8 wire 712 white. Locate the short and repair. B.

If continuity is found, the short to ground is in the feeder (FE) harness between connector X032 pin 20 and connector X007 pin 3 wire 712 white. Locate the short and repair. 10. Fault codes indicate circuit fault due to open circuit condition. Disconnect draper header solenoid connector X440. Measure the resistance of the motor between terminals 1 and 2. The correct resistance is XX - XX ohms . A. The resistance is infinite, indicating an open condition in the solenoid. Replace the solenoid. B. The resistance is in specification. Continue with Step 11 . 11. Ensure that the batteries are properly connected, and that fuse F23 is good.

Use a multimeter to check for continuity between connector X440 pin 2 and chassis ground. 9711 1 27/05/2004 K.25.D / 10