CROP PROCESSING - FEEDING Feeder housing A. If there is no continuity to ground, continue with Step 7 . B. If there is continuity to ground, continue with Step 9 . 7. Disconnect connector X011 . Use a multimeter to check for continuity between connector X011 pin 11 and chassis ground. Flex the main frame (MF) harness between the connector X011 and connector X019 while making this check. A. If there is continuity to ground, the open circuit is in the gearbox (GB) harness between connector X011 and connector X401 wire 1210 blue. Locate the open and repair. B. If there is no continuity to ground, continue with Step 8 . 8.
Disconnect connector X004 , and install a jumper wire between connector X004 pins 13 & 14. Use a multimeter to check for continuity between connector X011 pin 11 and chassis ground. Flex the main frame (MF) harness between the connector X011 and connector X019 while making this check. A. If there is continuity to ground, there is an open circuit in the cab main (CM) harness between connector X004 pins 13 & 14 and the feeder disengage relay K-19 wires 1210 blue or 875 blue. Locate the open and repair. B. If there is no continuity to ground, continue with Step 8 . 9. Disconnect connector X019 on the bottom of CCM1 module.
Use a multimeter to check for continuity between connector X019 pin J2-40 on the module and chassis ground. A. There is infinite resistance. The sense resistor in the CCM1 module has failed. Replace the module. B. There is less than 1 ohms resistance, indicating the sense resistor in the CCM1 module is okay. The open circuit is in the main frame (MF) harness between connector X011 , connector X004 and connector X019 wire 1210 blue or 875 blue. Locate the open and repair. NOTE: The sense resistor in the module for the Isense Feeder ETR Clutch circuit is easily damaged as a result of excessive current draw or a short to high voltage. 10. Turn the key switch to the ON position.
Use the Universal Display Plus "DIAG" screen controls to manually power the feeder ETR clutch valve. Use a multimeter to check for 12 volts between connector X401 pin A and chassis ground. A. If 12 volts is not present, continue with Step 10 . B. If 12 volts is found, continue with Step 11 . 11. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the Feeder ETR clutch valve. Use a multimeter to check for 12 volts between connector X011 pin 12 and chassis ground. A. If 12 volts is present, the open circuit is in the gearbox (GB) harness between connector X401 pin A and connector X011 pin 12 wire 876 white.
Locate the open circuit and repair. B. If 12 volts is not present, there is an open circuit in the main frame (MF) harness between connector X011 pin 12 and connector X019 pin J2-30 wire 876 white. Locate the open and repair. 12. Operate the combine while monitoring the Feeder ETR Clutch circuit current on the Universal Display Plus "DIAG" screen. A. If no high out of range current readings are seen, erase the error code and continue operation. 9712 1 27/05/2004 K.25.E / 75