Case IH AFX8010 — THRESHING Axial flow threshing

CROP PROCESSING - THRESHING Axial flow threshing Threshing rotor AFX (auger front) rotor - Balancing (K.40.C.52.52 - F.45.A.25) AFX8010 To ensure proper, vibration free operation, the rotor must be balanced. The rotor should be balanced when repairs have been made to the rotor body, such as repairs due to foreign object damage or if the front auger portion of the rotor has been repaired or replaced. Prior operation: Threshing rotor - Place on stand (K.40.C.52 - F.35.A.10) 1. Once the rotor is in the holding fixtures, spin the rotor slowly several times, noting where the rotor stops after each spin. If the rotor stops at the same point after each spin, the rotor is out of balance. 2.

If the rotor needs balanced, weld weights to the rear of the rotor. The weight should be added to the top (opposite) side of the rotor from where the rotor stopped. If more weight is necessary, weld weights to the front of the rotor. 10033729 1 3. Balance the rotor assembly complete with all parts bolted on. Use balance weights as required. NOTE: Balancing weights are not permitted between pairs of rasp bars where straight bars can be installed. 9714 1 27/05/2004 K.40.C / 32