DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM DE_DRC16-24S 47 9667 1 27/05/2004 A.30.A / 39 Cavity Circuit ID Description 1 052 (RD) Keep alive power from fuse F-39 2 198 (PU) Signal (L turn) from road light switch S-26 3 171 (YE) Signal from work light switch S-43 4 099 (OR) Power from key switch S-02 5 117 (WH) Output to road lights relay K-27, header work lights relay K-22 and lower work light relay K-30 6 692 (WH) Output to concave / covers relay K-16 7 112 (YE) Signal from feeder engage S-31 8 215 (BK) To cab ground 3 9 194 (PU) Signal (R turn) from road light switch S-26 10 open 11 190 (WH) Output to cab roof work lights relay K-01 and distance work lights relay K-21 12 181 (WH) Output to unload tube light relay K-32 13 138 (GN) CAN Low 14 137 (YE) CAN High 15 170 (YE) Signal from rear work light switch S-44 16 open 17 225 (YE) Signal from feeder engage diodes D-01 18 184 (WH) Output to rear work lights relay K-31 19 130 (GN) CAN Low 20 129 (YE) CAN High 21 212 (OR) Signal (marker) from road light switch S-26 22 open 23 107 (BK) Ground for power relays K-24, K-25 & K-26 (Reverse polarity protection) 24 180 (WH) Output to side work light relay K-35