CROP PROCESSING - THRESHING Axial flow threshing Command Threshing engage switch - Short circuit to B+ (K.40.C.05.80 - G.30.B.54) AFX8010 E0292-03 - Rotor CVT Pump Voltage Supply Cause: The Rotor CVT Pump Voltage Supply circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Rotor CVT Pump Voltage Supply wiring shorted to a high source. 2. Faulty alternator/regulator. 3. Controller internal failure (internal regulator failure). Solution: 1. Key ON, engine running. Move the separator switch S-30 to the ON position. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "CVT PUMP VOLT" to check the voltage range.
The proper voltage is 10.0 - 18.0 volts . A. If the voltage reading is greater than 18 volts , continue with Step 2 . B. If the voltage reading is between 10 and 18 volts , go to Step 5 . 2. Shut the combine OFF, and then turn the key switch back ON. Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM2 BAT" to check the voltage range. The acceptable voltage range for the module is 10 - 18 volts . A. If the voltage reading is between 10 - 18 volts , the alternator and/or regulator has failed, and is producing excessive voltage. Refer to Alternator - Problem solving (A.30.A.82 - G.40.A.30) for additional alternator testing information. B.
If the voltage reading is greater than 18 volts , continue with Step 3 . 3. Key switch in the "Off" position. Check the voltage at fuse F42 using a multi-meter. A. If the voltage reading is greater than 18 volts , then there is a fault in the wiring of the 24V starting system. Refer to STARTING SYSTEM - Problem solving (B.80.A - G.40.A.30) for additional information. B. If the voltage reading is between 10 - 18 volts , continue with Step 4 . 4. Key switch in the "On" position. Move the separator engage switch S-30 to the ON position. Remove the instructional seat and storage bin to gain access to connector X012 on CCM3. Check the voltage at connector X012 pin J1-17. A.
If the voltage reading is greater than 18 volts , then a high voltage source has been connected to one of the following wires:
- wire 109 orange, fuse F48 to relay K28, terminal 3 - wire 108 orange, fuse F48 through connector X001 pin 3 to RC harness splice - RH console power wires to propulsion handle S-03, front switch panel A-13, rear switch panel A-18 and RHM connector X026 pins 4 & 5 - wires 300 orange, 110 orange & 1180 orange, RH harness splice across separator switch S-30 to neutral switch S-02 connector X059 pin 3 - wires 147 yellow, 111 yellow & 1061 yellow, separator engage switch connector X055 pin 6 to CCM2 connector X015 pin J1-7 and connector X012 pin J1-7 - wire 1212 yellow, separator engage switch connector X055 pin 3 to connector X012 pin J1-17 - wire 302 yellow, separator engage switch connector X055 pin 3 to feeder engage switch connector X056 pin 5 9714 1 27/05/2004 K.40.C / 47