CROP PROCESSING - THRESHING Axial flow threshing Electrical control Relay - Unidentified failure (K.40.C.90.80 - G.30.B.46) AFX8010 E0069-11 - Covers / Concave Select Relay Cause: The covers/concave clearance relay (K-16) circuit open or shorted to ground. Possible failure modes: 1. Circuit connection/wiring damaged between CCM1 and relay. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "GRAIN HANDLING" or "THRESHING" sort menu, and select "COVERCONCAVE RLY". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON".
The "STATUS" screen should indicate "OK" if the circuit is working properly. A. If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 5 . 2. Turn the key switch to the OFF position and remove the covers/concave clearance relay K-16 from relay base in cab. Use a multimeter to check for continuity between relay base (K-16) pin 1 and chassis ground. Flex the cab main (CM) harness while making this check. A. If no continuity to ground is found, continue with Step 3 . B.
If there is continuity to ground, the short to ground is in the cab main (CM) harness between relay base and connector X018 J1-6 wire 692 white. Locate the short and repair. 3. Use a multimeter to check for continuity between relay base (K-16) pin 2 and chassis ground. A. If there is continuity to ground, continue with Step 4 . B. If no continuity to ground is found, there is an open circuit in the cab main (CM) harness between relay base pin 2 and cab ground #3 wire 697 black. Locate the open and repair. 4. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the covers/concave clearance relay K-16.
Use the multimeter to check for 12 volts between relay base (K-16) pin 1 and chassis ground. A. If 12 volts is not present, there is an open circuit in the cab main (CM) harness between the relay base K-16 and connector X018 J1-6 wire 692 white. Locate the open and repair. B. If 12 volts is found, continue with Step 5 . 5. Inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9714 1 27/05/2004 K.40.C / 104