CROP PROCESSING - THRESHING Axial flow threshing Sensing system Rotor speed sensor - Short circuit to B+ (K.40.C.95.80 - G.30.B.54) AFX8010 E0269-03 - Rotor Speed Sensor Cause: The Rotor RPM sensor (B-01) circuit signal wire is shorted to a higher than normal voltage source, or the ground wire is open. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Sensor ground wire is open. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "SPD SEN" to check the voltage range.

The proper voltage for sensor when blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage for sensor when not blocked by ferrous metal - 0.5 - 5.6 volts The proper voltage sensor disconnected 7.3 - 9.0 volts . A. If the voltage reading is high out of range 9.0 - 10.0 volts continue with Step 2 . B. If the voltage reading is within the proper limits, since the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 3 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.

Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the rotor RPM sensor connector X177 . A. If the voltage drops to 7.3 - 9.0 volts , continue with step 5 . B. If the voltage remains high, continue with step 3 . 3. Disconnect the main frame (MF) harness from the gearbox (GB) harness at connector X011 . A. If the voltage drops to 7.3 - 9.0 volts , there is a short in the gearbox (GB) harness between connector X011 and connector X177 wire 1261 yellow. Locate the short and repair. B. If the voltage remains high, continue with step 4 . 4. Disconnect the expansion (EX) harness from the main frame (MF) harness at connector X034A . A.

If the voltage drops to 7.3 - 9.0 volts , the short circuit is in the main frame (MF) harness between connector X011 pin 29, connector X016 pin J2-37, and connector X034A pin 10 wire 1261 yellow, 416 yellow or 1068 yellow. Locate short and repair. B. If the voltage remains high, the short circuit is in the expansion (EX) harness between connector X034A pin 10 and connector X014 pin J3-13 wire 1068 yellow. Locate short and repair. 5. Disconnect the rotor RPM sensor connector X177 . Use a multimeter to check for continuity between connector X177 pin C and chassis ground. A. If there is continuity to ground, the short is in the sensor or sensor wiring. Replace the sensor. B.

If there is no continuity to ground, continue with step 6 . 9714 1 27/05/2004 K.40.C / 120