CROP PROCESSING - THRESHING Axial flow threshing Sensing system Rotor speed sensor - Short circuit to ground (K.40.C.95.80 - G.30.B.53) AFX8010 E0269-04 - Rotor Speed Sensor Cause: The Rotor RPM sensor (B-01) circuit is shorted to ground. Possible failure modes: 1. Sensor supply wiring shorted to ground. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "SPD SEN" to check the voltage range.
The proper voltage sensor blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal - 0.5 - 5.6 volts The proper voltage with sensor disconnected - 7.3 - 9.0 volts . A. If the voltage reading is low ( 0 - 0.5 volts ) continue with Step 2 . B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 3 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2.
Disconnect the rotor RPM sensor connector X177 . A. If the voltage increases to 7.3 - 9.0 volts , the short is in the sensor or sensor wiring. Replace the sensor. B. If the voltage remains low, continue with step 3 . 3. Disconnect the main frame (MF) harness from the gearbox (GB) harness at connector X011 . A. If the voltage increases to 7.3 - 9.0 volts , there is a short in the gearbox (GB) harness between connector X011 and connector X177 wire 1261 yellow. Locate the short and repair. B. If the voltage remains low, continue with step 4 . 4. Disconnect the expansion (EX) harness from the main frame (MF) harness at connector X034A . A.
If the voltage increases to 7.3 - 9.0 volts , there is a short circuit in the main frame (MF) harness between connector X011 pin 29, connector X016 pin J2-37, and connector X034A pin 10 wire 1261 yellow, 416 yellow or 1068 yellow. Locate short and repair. B. If the voltage remains low, there is a short circuit in the expansion (EX) harness between connector X034A pin 10 and connector X014 pin J3-13 wire 1068 yellow. Locate short and repair. 5. Inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals for broken wires. A. If no damage is found, erase the fault code and continue operation. 9714 1 27/05/2004 K.40.C / 124