CROP PROCESSING - THRESHING Axial flow threshing Sensing system Hydrostat motor speed sensor - Open circuit (K.40.C.95.81 - G.30.B.50) AFX8010 E0270-05 - Rotor Motor Speed Sensor Cause: The Rotor hydrostat RPM sensor (B-58) circuit is open. Possible failure modes: 1. Sensor signal wiring is open. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "MTR SPD SEN" to check the voltage range.
The proper voltage sensor blocked by ferrous metal is 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal is 0.5 - 5.6 volts The proper voltage sensor disconnected is 7.3 - 9.0 volts . A. If the voltage reading is high 7.3 - 9.0 volts , continue with Step 2 . B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 4 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2.
Disconnect the rotor hydrostat RPM sensor connector X428 . Use a jumper wire to short the harness end of connector X428 pin 2 to chassis ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is in the sensor, or sensor wiring. Replace the sensor. B. If the monitor still displays 7.3 - 9.0 volts , continue with step 3 . 3. Disconnect the main frame (MF) harness from the gearbox (GB) harness at connector X011 . Use a jumper wire to short the main frame (MF) harness end of connector X011 pin 25 to chassis ground. A.
If the voltage drops to 0 - 0.5 volts indicating a ground, there is an open circuit in the gearbox (GB) harness between connector X011 pin 25 and connector X428 pin B wire 1069 yellow. Locate the open and repair. 4. Disconnect the expansion (EX) harness from the main frame (MF) harness at connector X034A . Use a jumper wire to short the harness end of connector X034A pin 7 to chassis ground. B. If the monitor still displays 7.3 - 9.0 volts , continue with step 4 . A. If the voltage drops to 0 - 0.5 volts indicating a ground, there is an open circuit in the main frame (MF) harness between connector X011 pin 25 and connector X034A pin 7 wire 1069 yellow. Locate open and repair. B.
If the monitor still displays 7.3 - 9.0 volts , there is an open circuit in the expansion (EX) harness between connector X034A pin 10 and connector X014 pin J3-14 wire 1068 yellow. Locate open and repair. 5. Inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals for broken wires. A. If no damage is found, erase the fault code and continue operation. 9714 1 27/05/2004 K.40.C / 137