CROP PROCESSING - STORING AND HANDLING Grain storing B. If 12 volts is not found, the open is in the cab main (CM) harness between connector X004 and relay base terminal 3 on relay K16, wire 696 white. Locate the open and repair. 31. Disconnect connector X289 at the grain tank covers motor. Use a multimeter to check for continuity between covers motor connector X289 pin A or B and chassis ground. There should not be any continuity to ground.. A. If there is continuity to ground, replace covers motor. B. If there is no continuity to ground, return to step 1 and repeat the covers motor circuit test. 32. Both concave and covers do not operate in either direction.
Fault code indicates an open circuit. Remove the concave/covers relay K-16 from the relay base. Operate the concave or grain tank covers using the Universal Display Plus "DIAG" screen controls. Use a multimeter to measure the voltage between relay base K-16 terminal 3 and chassis ground. A. If 12 volts is found, the open circuit is in the main frame (MF) harness between CCM1 connector X019 J2-1 and the MF wire splice wire 522 gray. Locate the open and repair. B. If 12 volts is not found, continue with Step 33 . 33. Disconnect connector X004 . Operate the concave or grain tank covers using the Universal Display Plus "DIAG" screen controls.
Use a multimeter to measure the voltage between connector X004 pin 29 and chassis ground. A. If 12 volts is found, the open is in the cab main (CM) harness between connector X004 and relay base K16 terminal 3. Locate the open and repair. B. If 12 volts is not found, the open is in main frame (MF) harness between connector X004 and CCM1 connector X019 J2-21 wire 523 white. Locate the open and repair. 34. If both the concave or grain tank covers do not operate in either direction, and there are no error codes indicated, the supply power for the circuits may not be present. Remove fuse F24 and inspect. A. Fuse has failed. Go to Step 35 . B. Fuse is okay. Go to Step 36 . 35.
If fuse has failed, replace the fuse. A. If fuse immediately fails, a short to ground exists in the cab main (CM) or main frame (MF) harnesses on one of the following wires; - wire 026 red, fuse F24 through connector X005 pin 2 to connector X019 pin J2-11 - wire 027 red, fuse F24 to connector X031 pin 3 Visually inspect the harnesses for damage, bent or dislocated pins, corroded terminals or broken wires. Locate the short to ground and repair. B. Fuse is okay. Go to Step 36 . 36. Test for 12V power at connector X019 pin J2-11 on the CCM1 module under the cab. A.
If there is no power, there is an open circuit in the cab main (CM) or main frame (MF) harnesses between fuse F24 through connector X005 pin 2 to connector X019 pin J2-11 wire 026 red. Visually inspect the harnesses for damage, bent or dislocated pins, corroded terminals or broken wires. Locate the open and repair. After repair, go to Step 37 . 37. Test for continuity to ground at connector X019 pin J2-3 on the CCM1 module under the cab. B. If there is power, go to Step 37 . A. If there is no continuity to ground, there is an open circuit in the front frame (FF) harness between connector X019 pin J2-3 and the front frame ground #2 wire 513 black. Locate the open and repair.
After repair, go to Step 38 . B. If there is continuity to ground, go to Step 38 . 38. Operate the concave or grain tank covers using the Universal Display Plus "DIAG" screen controls. A. If the fuse fails during the testing, a short to ground on the circuit is causing the fuse to fail. Start the troubleshooting at Step 1 to locate the short to ground. 9716 1 27/05/2004 K.60.B / 59