CROP PROCESSING - STORING AND HANDLING Grain storing E0159-03 - Grain Tank Full Sensor E0159-05 - Grain Tank Full Sensor When the threshing system is engaged, and the grain bin 3/4 full switch S-28 is closed, the "Bin Full" light will illuminate on the shaft speed monitor, and the rotating beacons (if equipped) will flash to alert a grain truck operator to prepare for unloading the grain bin, and will continue to flash until the grain bin is emptied. NOTE: If the work lights are activated, the rotating beacons will only flash for approximately 10 seconds when the grain bin 3/4 full switch is closed, and will flash again for approximately 10 seconds when the grain bin full switch is closed.
When the material level closes the grain bin full switch S-29, the "Bin Full" light on the shaft speed monitor will flash, and a buzzer will sound. The alarm message "A0030 Grainbin FULL" will also be displayed to the operator. 9716 1 27/05/2004 K.60.B / 70