Case IH AFX8010 — STORING AND HANDLING Grain storing

CROP PROCESSING - STORING AND HANDLING Grain storing Sensing system Grain tank covers sensor - Short circuit to ground (K.60.B.95.82 - G.30.B.53) AFX8010 E0001-04 - Grain Tank Covers Open Sensor Cause: The bin covers open sensor (B47) circuit is shorted to ground. Possible failure modes: 1. Sensor supply wiring shorted to ground. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "GRAIN HANDLING" sort menu, and select "COVERS OPEN SEN" to check the voltage range. The proper voltage for covers open - 5.6 - 7.3 volts The proper voltage for covers closed - 0.5 - 5.6 volts A.

If the voltage reading is low ( 0 - 0.5 volts ), continue with Step 2 . 2. Disconnect the covers closed proximity sensor connector X288 in the grain bin. B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 5 . A. If the voltage increases to 7.3 - 9.0 volts the short is in the sensor, or sensor wiring. Replace the sensor. 3. Disconnect the connector X195 . B. If the voltage remains low, continue with Step 3 . A. If the voltage increases to 7.3 - 9.0 volts , the short to ground is in the jumper harness between connector X195 and connector X288 wire 435 yellow. Locate the short and repair. B. If the voltage remains low, continue with Step 3 . 4.

Disconnect the connector X008 . A. If the voltage increases to 7.3 - 9.0 volts , the short to ground is in the main frame (MF) harness between connector X008 and connector X195 wire 435 yellow. Locate the short and repair. B. If the voltage remains low, the short to ground is in the front frame (FF) harness between connector X008 and connector X020 J3-38 wire 435 yellow. Locate the short and repair. 5. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9716 1 27/05/2004 K.60.B / 78