Case IH AFX8010 — STORING AND HANDLING Grain storing

CROP PROCESSING - STORING AND HANDLING Grain storing Sensing system Speed sensor - Open circuit (K.60.B.95.81 - G.30.B.50) AFX8010 E0016-05 - Clean Grain Elevator Speed Sensor Cause: The clean grain elevator RPM sensor (B08) circuit is open. Possible failure modes: 1. Sensor supply wiring is open. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "GRAIN HANDLING" sort menu, and select "ELEVATOR SPD SEN" to check the voltage range.

The proper voltage for sensor unblocked by ferrous metal is 0.5 - 5.6 volts The proper voltage for sensor blocked by ferrous metal is 5.6 - 7.3 volts The proper voltage with sensor disconnected is 7.3 - 9.0 volts . A. If the voltage reading is high 7.3 - 9.0 volts , continue with Step 2 . B. If the voltage reading is within the proper limits, the open is not present at this time. Continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.

Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the clean grain elevator RPM sensor connector X182 . Use a jumper wire to short the harness end of connector X182 pin 2 to chassis ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is not in the supply side of the circuit. Continue with Step 3 . B. If the monitor still displays 7.3 - 9.0 volts , the open circuit is in the main frame (MF) harness between connector X182 pin 2 and connector X019 pin J2-28 wire 450 yellow. Locate the open and repair. 3. Disconnect the clean grain elevator RPM sensor connector X182 .

Use a multimeter to check for continuity between the harness end of connector X182 pin 1 and chassis ground. A. If there is continuity, the ground path for the sensor is complete, and the fault is in the sensor itself. Replace the sensor. B. If there no is continuity, there is an open circuit in the main frame (MF) harness between connector X181 pin 1 and connector X019 pin J2-14 wire 491 blue, 401 blue or 460 blue.. Locate the open and repair. 4. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9716 1 27/05/2004 K.60.B / 92