CROP PROCESSING - CLEANING Primary cleaning 15. Set the grain sensing pad (1) into position and secure using the four locknuts (2) previously removed. Plug in the sensing pad electrical connector. ATTENTION: Lower Connecting Arm Bushings Install 20013945 10 16. Press the new bushing (1) onto the journal (2) until the bottom of the center metal insert is 22 - 24 mm ( 7/8 - 15/16 in ) from the surface of the mounting plate. 40015729z 11 17. Attach the mounting plate (1) to the lower cleaning shoe with the previously removed hardware. 18. Install bushing cap (2) on both sides of the combine. Do not tighten the hardware. 10036376 12 10036373 13 9717 1 27/05/2004 K.62.B / 20