Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning Fan - Disassemble (K.62.B.52 - F.10.A.25) AFX8010 Prior operation: Fan - Remove (K.62.B.52 - F.10.A.10) 1. Remove the nine M8 x 20mm bolts from the two piece fan housing (1) to separate the halves from the fan (2) . 2. When the fan assembly is out of the housing remove the speed sensor, pickup lock collar (5) , and sensor bracket (3) from the right hand side of the fan assembly. Remove the four M12 x 35mm bolts securing the flangettes (2) to the bearing (4) and support bracket (1) on the right hand side. 50042974A5 1 50042972A5 2 3.

Remove the bearing lock collar (4) , bearing (3) , flangettes (2) , and bearing support bracket (1) from the fan assembly shaft on the left hand side. 50042973A5 3 9717 1 27/05/2004 K.62.B / 35