CROP PROCESSING - CLEANING Primary cleaning B. If no continuity is found, there is an open circuit in the lower frame (LF) harness between connector X088 pin C and connector X023 pin 15 wire 721 yellow. Locate the open and repair. 7. Carefully disconnect connector X020 from the bottom of the CCM1 module. Use a multimeter to check for continuity between connector X023 pin 15 and connector X020 pin J3-32. There should be continuity. A. If continuity is found, the open is in the sensor. Replace the sensor. B. If no continuity is found, there is an open circuit in the front frame (FF) harness between connector X023 pin 15 and connector X020 pin J3-32 wire 721 yellow. Locate the open and repair.
8. Operate the machine while monitoring the Universal Display Plus "DIAG" screen, "SIEVE ANG SEN" voltage. A. If no low out of range reading are indicated, erase the fault code and continue operation. Motor Shoe leveling motor - Overview (K.62.B.28.60 - C.10.A.10) 40033773A5 1 The shoe leveling actuator M-03 (1) is located in front of the cleaning fan on the right side, and is attached between the right side frame and the cleaning shoe. The shoe leveling actuator contains an electrical motor, used to extend and retract the actuator in order to tilt the cleaning shoe, and a linear potentiometer to monitor the angle at which the cleaning shoe is tilted.
The shoe leveling actuator is connected ( X088 ) to the lower frame (LF) harness at (2) , and is connected to the CCM1 module at connector X020 as follows: The CCM1 module uses two pairs of pins to send current to the shoe leveling actuator motor. This allows the CCM1 module to reverse the polarity and change the direction of the actuator. The CCM1 module software detects when the self-leveling cleaning shoe makes contact with the frame by detecting when the actuator motor is stalled (sudden amperage increase), and establishes the limit of travel based on input from the potentiometer in the actuator.
These limits are NOT stored in non-volatile memory, so they are established at least once (each direction) for every key-on cycle. The shoe leveling actuator M-03 circuit (both motor and potentiometer) is also monitored by the CCM1 module; in the event that a fault occurs with the actuator or wiring to the actuator, a fault code will be displayed to the operator.
E0032-03 - Sieve Angle Sensor E0032-05 - Sieve Angle Sensor E0043-06 - Sieve Angle Current Sense E0075-11 - Leveling Sieve 9717 1 27/05/2004 K.62.B / 81 Shoe leveling actuator function Pin number at CCM1 connector X020 Motor, extend J3-39, J3-40 = power; J3-19, J3-20 = ground Motor, retract J3-19, J3-20 = power; J3-39, J3-40 = ground Potentiometer J3-32