Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning A. Refer to the appropriate repair manual chapter for repair and adjustment of the self leveling shoe assembly. 3. Fault codes indicate circuit fault due to short to ground. Disconnect the shoe leveling actuator connector X088 . Use a multimeter to check for continuity between the actuator side of connector X088 pins D and E and chassis ground. There should not be any continuity to ground. A. If there is continuity to ground, there is a short to ground in the actuator. Replace the shoe leveling actuator. 4. Disconnect the batteries by removing the negative battery cables.

Use a multimeter to check for continuity between the harness end of connector X088 pin E and chassis ground. There should not be any continuity to ground. B. If there is no continuity to ground, continue with step 4 . A. If continuity is found, continue with step 5 . B. If no continuity is found, continue with step 6 . NOTE: The CCM module connects both sides of the circuit to ground when in neutral to "lock" the actuator in position. Power must be removed from the module prior to testing for short to ground condition on the actuator circuit to remove this ground path. 5. Disconnect connector X023 .

Use a multimeter to check for continuity between the front frame (FF) harness end of connector X023 pin 1 and chassis ground. There should not be any continuity to ground. A. If no continuity is found, there is a short to ground in the lower frame (LF) harness between connector X023 pin 1 and connector X088 pin E wire 707 grey. Locate the short and repair. B.

If continuity is found, there is a short to ground in the front frame (FF) harness between connector X023 pin 1 and connector X020 pins J3-19 and J3-20 on one of the following wires; wire 707 grey, connector X023 pin 1 to FF harness splice, wire 705 grey, harness splice to connector X020 pin J3-19, and wire 706 grey, connector X020 pin J3-20. Locate the short and repair. 6. Disconnect connector X088 . Use a multimeter to check for continuity between the harness end of connector X088 pin D and chassis ground. There should not be any continuity to ground. A. If continuity is found, continue with step 7 . B. If no continuity is found, recheck the actuator for continuity to ground at step 3 . 7.

Disconnect connector X023 . Use a multimeter to check for continuity between the front frame (FF) harness end of connector X023 pin 2 and chassis ground. There should not be any continuity to ground. A. If no continuity is found, there is a short to ground in the lower frame (LF) harness between connector X023 pin 2 and connector X088 pin D wire 710 white. Locate the short and repair. B.

If continuity is found, there is a short to ground in the front frame (FF) harness between connector X023 pin 2 and connector X020 pins J3-39 and J3-40 on one of the following wires; wire 710 white, connector X023 pin 2 to FF harness splice, wire 708 white, harness splice to connector X020 pin J3-39, and wire 709 white, connector X020 pin J3-40. Locate the short and repair. 8. Fault codes indicate circuit fault due to open circuit condition. Disconnect the shoe leveling actuator connector X088 . Use a multimeter to measure the resistance between the actuator end of connector X088 pins D and E. The correct resistance is 1 - 5 ohms . A.

If the resistance is infinite, there is an open condition in the actuator. Replace the shoe leveling actuator. B. If the resistance is within specification, continue with step 9 . 9. Ensure that the batteries cables are securely connected, and that fuse F-22 is good. Use a multimeter to check for continuity between the harness end of connector X088 pin E and chassis ground. There should be continuity to ground. A. If continuity is found, continue with step 11 . B. If no continuity is found, continue with step 10 . 9717 1 27/05/2004 K.62.B / 86