CROP PROCESSING - CLEANING Primary cleaning Motor Shoe leveling motor - Unidentified failure (K.62.B.28.60 - G.30.B.46) AFX8010 E0075-11 - Leveling Sieve Cause: The shoe leveling actuator M-03 circuit indicates high current draw. Possible failure modes: 1. Circuit connection shorted to ground. 2. Excessive mechanical load on actuator. 3. Controller internal failure (internal regulator failure). Solution: 1. This is an H-bridge controlled circuit, which reverses the power and ground connections to the shoe leveling actuator in order to move it in either direction.
The CCM module monitors both sides of the circuit during operation, and issues one or both fault codes, depending on the failure type detected. Use the following procedure to determine the location of the fault. A. If the shoe leveling actuator operates in one direction only, and the fault code E0043-06 - Sieve Angle Current Sense is displayed, continue with step 2 . B. If the shoe leveling actuator operates in one direction only, and both fault codes E0043-06 - Sieve Angle Current Sense and E0075-11 - Leveling Sieve are displayed, continue with step 3 . C.
If the shoe leveling actuator does not operate in either direction, and the fault code E0043-06 - Sieve Angle Current Sense is displayed, continue with step 2 . D. If the shoe leveling actuator does not operate in either direction, and both fault codes E0043-06 - Sieve Angle Current Sense and E0075-11 - Leveling Sieve are displayed, continue with step 8 . E. If the shoe leveling actuator does not operate in either direction, and no fault codes are displayed, continue with step 13 . 9717 1 27/05/2004 K.62.B / 91 Step Description 1 Enter the Universal Display Plus "ERROR" screen. Record the error list, and then select "CLEAR". Clear all errors from the CCM1 module.
2 Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "LEVELING SIEVE". Start the combine, and use the "COMMAND" and "ENGAGE" functions to manually tilt the cleaning shoe in each direction. Record in which directions the shoe leveling actuator operates. 3 Enter the Universal Display Plus "ERROR" screen, and depress the "REFRESH" button to update the error history. Check for fault codes E0043-06 - Sieve Angle Current Sense and E0075-11 - Leveling Sieve . 4 Use the appropriate result below to determine the location of the fault.