CROP PROCESSING - CLEANING Primary cleaning B. If no continuity is found, continue with Step 36 . 36. Disconnect connector X025 . Use a multimeter to check for continuity between connector X025 pin 14 and chassis ground. A. If continuity is found, the open circuit is in the straw hood front (SW) harness between connector X072 pin J and connector X025 pin 14 wires 791 gray or 785 gray. Locate the open and repair. B. If no continuity is found, the open circuit is in the expansion (EX) harness between connector X025 pin 14 and connector X013 pin J2-1 wire 785 gray. Locate the open and repair. 37. Use a multimeter to check for continuity between connector X227 pin D and chassis ground. A.
If no continuity is found, continue with Step 38 . B. If continuity is found, recheck the motor for continuity at Step 37 . Erase the fault codes and continue operation. 38. Disconnect connector X072 . Use a multimeter to check for continuity between connector X072 pin H and chassis ground. A. If continuity is found, the open circuit is in the lower frame rear (LR) harness between connector X227 pin D and connector X072 pin H wire 792 white. Locate the open and repair. B. If no continuity is found, continue with Step 39 . 39. Disconnect connector X025 . Use a multimeter to check for continuity between connector X025 pin 17 and chassis ground. A.
If continuity is found, the open circuit is in the straw hood front (SW) harness between connector X072 pin H and connector X025 pin 17 wire 792 white. Locate the open and repair. B. If no continuity is found, continue with Step 40 . 40. Disconnect connector X219 . Use a multimeter to check for continuity between connector X219 pin 3 and chassis ground. A. If continuity is found, the open circuit is in the expansion (EX) harness between connector X025 pin 17 and connector X219 pin 3 wire 792 white. Locate the open and repair. B. If no continuity is found, continue with Step 41 . 41. Remove the upper/lower sieve relay K18 from the fuse panel.
Use a multimeter to check for continuity between Upper/lower sieve relay K18 terminal 4 and chassis ground. A. If no continuity is found, the open circuit is in the cab main (CM) or main frame (MF) harness wire 792 white from the fuse panel through connector X005 pin 17 to connector X219 pin 3. Locate the open and repair. B. If continuity is found, continue with Step 42 . NOTE: Continuity check is being done back through circuit through the motor. The resistance will read significantly higher than previous tests, but should not be higher than 10 ohms above the motor resistance measured in Step 33. 42. Reconnect connector X005 .
Use a multimeter to check for continuity between Upper/lower sieve relay K18 terminal 3 and chassis ground. A. If continuity is found, the relay has failed open between terminals 3 and 4. Replace the relay. B. If no continuity is found, continue with Step 43 . 43. Disconnect connector X005 . Use a multimeter to check for continuity between connector X005 pin 15 and chassis ground. A. If continuity is found, the open circuit is in the cab main (CM) harness between the Upper/lower sieve relay K18 terminal 3 on the fuse panel and connector X005 pin 15 wire 786 red. Locate the open and repair. B. If no continuity is found, continue with Step 44 . 9717 1 27/05/2004 K.62.B / 114