Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning 28. Fault codes indicate circuit fault due to short to ground between the upper sieve motor and the Upper/lower sieve relay K18. Disconnect the batteries by removing the negative battery cables. Unplug the upper sieve motor connector X227 . Use a multimeter to check for continuity between connector X227 pin D and chassis ground. A. If continuity is found, continue with Step 33 . B. If no continuity is found, erase the fault codes and continue operation. NOTE: The CCM module connects both sides of the circuit to ground when in neutral to "lock" the motor in position.

Power must be removed from the module prior to testing for short to ground condition on the motor circuit to remove this ground path. 29. Disconnect connector X072 . Use a multimeter to check for continuity between connector X072 pin H and chassis ground. A. If no continuity is found, the short to ground is in the lower frame rear (LR) harness between connector X227 pin D and connector X072 pin H wire 792 white. Locate the short and repair. B. If continuity is found, continue with Step 34 . 30. Disconnect connector X025 . Use a multimeter to check for continuity between connector X025 pin 17 and chassis ground. A.

If no continuity is found, the short to ground is in the straw hood front (SW) harness between connector X072 pin H and connector X025 pin 17 wire 792 white. Locate the short and repair. 31. Disconnect connector X219 . Use a multimeter to check for continuity between connector X219 pin 3 and chassis ground. B. If continuity is found, continue with Step 35 . A. If no continuity is found, the short to ground is in the expansion (EX) harness between connector X025 pin 17 and connector X219 pin 3 wire 792 white. Locate the short and repair. B. If continuity is found, continue with Step 36 . 32. Disconnect connector X005 .

Use a multimeter to check for continuity between connector X005 pin 17 and chassis ground. A. If no continuity is found, the short to ground is in the main frame (MF) harness between connector X219 pin 3 and connector X005 pin 17 wire 792 white. Locate the short and repair. B. If continuity is found, the short to ground is in the cab main (CM) harness between connector X005 pin 17 and the Upper/lower sieve relay K18 pin 4 on the fuse panel wire 792 white. Locate the short and repair. 33. Fault codes indicate circuit fault due to open circuit condition. Disconnect the upper sieve motor connector X227 . Measure the resistance of the motor between terminals A and B.

The correct resistance is 3 - 12 ohms . A. The resistance is infinite, indicating an open condition in the motor. Replace the upper sieve motor. B. The resistance is in specification. Continue with Step 38 . 34. Ensure that the batteries are connected, and that fuse F27 is good. Use the multimeter to check for continuity between connector X227 pin E and chassis ground. A. If continuity is found, continue with Step 37 . B. If no continuity is found, continue with Step 35 . NOTE: The CCM module connects both sides of the circuit to ground when in neutral to "lock" the motor in position, irregardless of key switch position, as long as it receives power through fuse F27.

This ground path may be used to test for an open circuit condition. 35. Disconnect connector X072 . Use a multimeter to check for continuity between connector X072 pin J and chassis ground. A. If continuity is found, the open circuit is in the lower frame rear (LR) harness between connector X072 pin J and connector X227 pin E wire 791 gray. Locate the open and repair. 9717 1 27/05/2004 K.62.B / 124