Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning Motor Upper sieve motor - Unidentified failure (K.62.B.28.55 - G.30.B.46) AFX8010 E0335-11 - Upper Sieve Context: This is an H-bridge-controlled circuit which reverses the power and ground connections to the sieve motors in order to move them in either direction. The lower sieve motor (M07) circuit is paired with the upper sieve motor (M06) circuit, and the module switches between these two circuits using the Upper/Lower sieve relay K-18. Because these circuits are connected and driven from the same module outputs, the troubleshooting procedure must consider both circuits at the same time. Cause:

The upper sieve motor (M-06) circuit is open, or shorted to ground. Possible failure modes: 2. Excessive mechanical load on motor. 1. Circuit wiring open or shorted to ground. 3. Controller internal failure (internal regulator failure). Solution: 1. A. If the lower sieve operates in one direction only, and the fault code E0300-06 - Lower Sieve Current Sense is displayed, continue with step 2 . B. If the lower sieve operates in one direction only, and both fault codes E0300-06 - Lower Sieve Current Sense and E0334-11 - Lower Sieve are displayed, continue with step 3 . C.

If the lower sieve and upper sieve both operate in one direction only, and the fault codes E0300-06 - Lower Sieve Current Sense , E0301-06 - Upper Sieve Current Sense , 9717 1 27/05/2004 K.62.B / 130 Step Description 1 Enter the Universal Display Plus "ERROR" screen. Record the error list, and then select "CLEAR". Clear all errors from the CCM1 module. 2 Enter the Universal Display Plus "DIAG" screen. Select the "SIEVE" sort menu, and select "LOW MTR". Start the combine, and use the "COMMAND" and "ENGAGE" functions to manually operate the lower sieve in each direction. Record in which directions the lower sieve actuator operates.

3 Select "UP MTR", and use the "COMMAND" and "ENGAGE" functions to manually operate the upper sieve in each direction. Record in which directions the upper sieve actuator operates. 3 Enter the Universal Display Plus "ERROR" screen, and depress the "REFRESH" button to update the error history. Check for the following fault codes: E0300-06 - Lower Sieve Current Sense E0301-06 - Upper Sieve Current Sense E0334-11 - Lower Sieve E0335-11 - Upper Sieve . 4 Use the appropriate result below to determine the location of the fault.