CROP PROCESSING - CLEANING Primary cleaning Fan drive system - Unidentified failure (K.62.B.40 - G.30.B.46) AFX8010 E0054-11 - Cleaning Fan Valve Cause: The fan drive solenoid (L-44) circuit is open or shorted to ground. Possible failure modes: 1. Supply wiring shorted to ground or open circuit. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "FAN VLV". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A.
If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . 2. Turn the key switch to the OFF position and disconnect the fan drive solenoid connector X444 . Use a multimeter to check the resistance of the fan drive solenoid. The proper resistance range for the coil is 1.0 - 8.0 ohms . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 7 . A. If out of specification, replace coil. B. If the coil is within specification, continue with Step 3 . 3. Use a multimeter to check for continuity between the main frame (MF) harness end of connector X444 pin 1 and chassis ground.
Flex the main frame (MF) harness while making this check. A. If no continuity to ground is found, continue with Step 4 . B. If there is continuity to ground, there is a short to ground in the main frame (MF) harness between connector X444 and connector X019 pin J2-13 wire 1161 white. Locate the short and repair. 4. Use a multimeter to check for continuity between the main frame (MF) harness end of connector X444 pin 2 and chassis ground. Flex the main frame (MF) harness while making this check. A. If continuity to ground is found, continue with Step 4 . B.
If there is no continuity to ground, there is an open circuit in the main frame (MF) harness between connector X444 and front frame ground #2 wire 1192 black. Locate the open and repair. 5. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the fan drive solenoid. Use a multimeter to check for 12 volts between connector X444 pin 1 and chassis ground. A. If 12 volts is not present, there is an open circuit in the main frame (MF) harness between connector X444 and connector X019 pin J2-13 wire 1161 white. Locate the open and repair. B. If 12 volts is found, continue with Step 7 . 6.
Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9717 1 27/05/2004 K.62.B / 141