Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning Electrical control Relay - Unidentified failure (K.62.B.90.80 - G.30.B.46) AFX8010 E0325-11 - Upper / Lower Sieve Select Relay Cause: The Upper/Lower Sieve Select Relay (K-18) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad relay. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "SIEVE" sort menu, and select "UP/LOW RLY". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A.

If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 7 . 2. Turn the key switch to the OFF position and remove the Upper/Lower Sieve Select Relay K-18. Use a multimeter to check the resistance of the upper/lower sieve relay coil. The proper resistance range for the Upper/Lower Sieve Select relay coil is 74.3 - 78.3 ohms . A. If out of specification, replace relay. B. If the coil is within specification, continue with Step 3 . 3. Use a multimeter to check for continuity between relay socket pin 1 and chassis ground. A.

If no continuity to ground is found, continue with Step 4 . B. If there is continuity to ground, there is a short to ground in the cab main (CM) harness between the fuse panel and connector X012 pin J1-6 wire 787 white. Locate the short and repair. 4. Use a multimeter to check for continuity between relay socket pin 2 and chassis ground. A. If continuity to ground is found, continue with Step 5 . B. If there is no continuity to ground, there is an open circuit in the cab main (CM) harness between the fuse panel and cab ground #3 wire 788 black. Locate the open and repair. 5. Turn the key switch to the ON position.

Use the Universal Display Plus "DIAG" screen controls to manually power the upper/lower sieve relay. Use the multimeter to check for 12 volts between relay socket pin 1 and chassis ground. A. If 12 volts is not present, continue with Step 6 . B. If 12 volts is found, continue with Step 7 . 6. Key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the upper/lower sieve relay. Use the multimeter to check for 12 volts between connector X012 J1-6 and chassis ground. A. If 12 volts is not present, replace the CCM3 with a known good controller. B.

If 12 volts is present, there is an open circuit in the cab main (CM) harness between connector X012 J1-6 and relay socket pin 1 wire 787 white. Locate the open and repair. 9717 1 27/05/2004 K.62.B / 144