CROP PROCESSING - CLEANING Primary cleaning Sensing system Lateral inclination sensor - Open circuit (K.62.B.95.50 - G.30.B.50) AFX8010 E0033-05 - Lateral Inclination Sensor Cause: The lateral inclination sensor B-02 circuit is open or shorted to ground. Possible failure modes: 1. Sensor signal wiring is open or shorted to ground. 2. Loss of power to the sensor. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "LATERAL TILT SEN" to check the voltage range. The normal operating voltage range is 0.3 - 5.2 volts . A.
If the voltage reading is low ( 0.3 volts ) out of range, continue with step 2 . B. If the voltage reading is within the proper limits, the circuit may not be open or shorted to ground at this time. Continue the troubleshooting at step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Key on. Disconnect connector X170 , and use a multimeter to check for voltage on connector X170 pin A. There should be 5 volts present. A.
If 5 volts is found, continue with step 3 . B. If no voltage is found, there is an open circuit in the main frame (MF) harness between connector X170 pin A and connector X019 pin J2-31 wire 451 pink or 453 pink. Locate the open and repair. Locate the open and repair. 3. Key off. Disconnect connector X170 . Use a multimeter to check for continuity between connector X170 pin C and chassis ground. There should not be any continuity. A. If no continuity is found, there is a short to ground in the main frame (MF) harness between connector X170 pin C and connector X019 pin J2-33 wire 430 yellow. Locate the short and repair. 4. Key off.
Carefully disconnect connector X019 from the bottom of the CCM1 module. Use a multimeter to check for continuity between X170 pin C and connector X019 pin J2-33. There should be continuity. A. If continuity is found, the open circuit is in the sensor. Replace the sensor. B. If no continuity is found, there is an open circuit in the main frame (MF) harness between connector X170 pin C and connector X019 pin J2-33 wire 430 yellow. Locate the open and repair. 5. Operate the machine while monitoring the Universal Display Plus "DIAG" screen, "LATERAL TILT SEN" voltage range. A. If no low out of range readings are indicated, erase the fault code and continue operation.
9717 1 27/05/2004 K.62.B / 151